Model & Order Number

Models and MLFB Order Numbers

Order No. (MLFB)Model / TypeDescriptionStatus
7SD6101-5FB19-0ST1 M1J Circuit Breaker LINE-DIFFERENTIAL PROT. RELAY FOR TWO LINE TERMINALS CURRENT TRANSFORMER: IPH = 1A, IE = 1A AUXILIARY VOLTAGE: 110V-250V DC 115V TO 230V AC, BINARY INPUT THRESHOLD 88V, SURFACE-MOUNTING CASE WITH 2-TIER TERMINALS 1/3 X 19", 7 BINARY INPUTS, 5 BINARY OUTPUTS, 1 LIVE-STATUS CONTACT REGION WORLD, LANGUAGE ENGLISH (LANGUAGE SELECTABLE) IEC PROTOCOL, ELECTRIC RS232 INTERFACE ON REAR SIDE DIGSI 4, ELECTRIC RS232 PROTECTION DATA INTERFACE 1: OPTICAL 1550NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 100 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIPPING 3-POLE ONLY, WITHOUT AUTO-RECLOSURE WITH DIRECTIONAL EMERGENCY/BACKUP OVERCURRENT-TIME PROTECTION/ WITH BREAKER FAILURE PROTECTION WITH 4 REMOTE COMMANDS/SIGNALS, WITH 24 REMOTE INDICATIONS, WITH TRANSFORMER EXTENSIONS (VECTOR GROUP ADAPTION) WITH VOLTAGE-/FREQUENCY PROTEC. WITH RESTRICTED EARTH FAULT WITH EXTERNAL GPS-SYCHRONIZAT. OF DIFFERENTIAL PROTECTION In stock
7SD6105-5BB29-0CA0 M2A Circuit Breaker LINE-DIFFERENTIAL PROT. RELAY FOR TWO LINE TERMINALS CURRENT TRANSFORMER: IPH = 5A, IE = 5A AUXILIARY VOLTAGE: 110V-250V DC 115V TO 230V AC, BINARY INPUT THRESHOLD 88V, FLUSH-MOUNTING CASE WITH SCREW TERMINALS, 1/3 X 19", 7 BINARY INPUTS, 5 BINARY OUTPUTS, 1 LIVE-STATUS CONTACT REGION WORLD, LANGUAGE ENGLISH (LANGUAGE SELECTABLE) IEC PROTOCOL, ELECTRIC RS485 INTERFACE ON REAR SIDE DIGSI 4, ELECTRIC RS485 PROTECTION INTERFACE 1: OPTICAL 820NM, 2 ST-CONNECTORS FO-LENGHT UP TO 1,5KM; FOR DIRECT CONNECTION OR VIA COMMUNICATION NETWORKS FUNCTION 1: TRIPPING 3-POLE ONLY, WITHOUT AUTO-RECLOSURE WITH EMERGENCY/BACKUP OVERCURRENT-TIME PROTECTION/ WITH BREAKER FAILURE PROTECTION WITHOUT REMOTE COMMANDS/SIGNALS WITHOUT TRANSFORMER EXTENSIONS W/O EXTERNAL GPS-SYNCHRONIZAT. OF DIFFERENTIAL PROTECTION In stock
7SD6105-5BB99-0CN0 L0R+M2B Circuit Breaker LINE-DIFFERENTIAL PROT. RELAY FOR TWO LINE TERMINALS CURRENT TRANSFORMER: IPH = 5A, IE = 5A AUXILIARY VOLTAGE: 110V-250V DC 115V TO 230V AC, BINARY INPUT THRESHOLD 88V, FLUSH-MOUNTING CASE WITH SCREW TERMINALS, 1/3 X 19", 7 BINARY INPUTS, 5 BINARY OUTPUTS, 1 LIVE-STATUS CONTACT REGION WORLD, LANGUAGE ENGLISH (LANGUAGE SELECTABLE) IEC 61850,100 MBIT ETHERNET ELECTRICAL,DOUBLE, RJ45-PLUG INTERFACE ON REAR SIDE DIGSI 4, ELECTRIC RS485 PROTECTION INTERFACE 1: OPTICAL 820NM, 2 ST-CONNECTORS FO-LENGHT UP TO 3,5KM; FOR DIRECT CONNECTION VIA MULTIMODE FIBER FUNCTION 1: TRIPPING 3-POLE ONLY, WITHOUT AUTO-RECLOSURE WITH EMERGENCY/BACKUP OVERCURRENT-TIME PROTECTION/ WITH BREAKER FAILURE PROTECTION WITH 4 REMOTE COMMANDS/SIGNALS, WITH 24 REMOTE INDICATIONS, WITH TRANSFORMER EXTENSIONS (VECTOR GROUP ADAPTION) W/O EXTERNAL GPS-SYNCHRONIZAT. OF DIFFERENTIAL PROTECTION In stock
7SD6105-5BB99-3ST1 L0S+M2J Circuit Breaker LINE-DIFFERENTIAL PROT. RELAY FOR TWO LINE TERMINALS CURRENT TRANSFORMER: IPH = 5A, IE = 5A AUXILIARY VOLTAGE: 110V-250V DC 115V TO 230V AC, BINARY INPUT THRESHOLD 88V, FLUSH-MOUNTING CASE WITH SCREW TERMINALS, 1/3 X 19", 7 BINARY INPUTS, 5 BINARY OUTPUTS, 1 LIVE-STATUS CONTACT REGION WORLD, LANGUAGE ENGLISH (LANGUAGE SELECTABLE) IEC 61850,100 MBIT ETHERNET WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR (FROM OCT. 09) INTERFACE ON REAR SIDE DIGSI 4, ELECTRIC RS485 PROTECTION DATA INTERFACE 1: OPTICAL 1550NM,LC-DUPLEX CONNE. FIBER LENGTH UP TO 100 KM FOR DIRECT CONNECTION VIA MONO-MODE FIBER FUNCTION 1: TRIPPING 1- AND 3-POLE, WITH AUTO-RECLOSURE WITH DIRECTIONAL EMERGENCY/BACKUP OVERCURRENT-TIME PROTECTION/ WITH BREAKER FAILURE PROTECTION WITH 4 REMOTE COMMANDS/SIGNALS, WITH 24 REMOTE INDICATIONS, WITH TRANSFORMER EXTENSIONS (VECTOR GROUP ADAPTION) WITH VOLTAGE-/FREQUENCY PROTEC. WITH RESTRICTED EARTH FAULT WITH EXTERNAL GPS-SYCHRONIZAT. OF DIFFERENTIAL PROTECTION In stock
7SD8011-5BB20-1FA0 Circuit Breaker Line differential protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Surface mounting enclosure screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) IEC60870-5-103 or DIGSI4/modem or time synchronization, electrical RS 485 without further communication interface for Port A Measurement: fault recording Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>,I>>>, Ip Time-overcurrent protection ground In>.In>>,In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V Underfrequency/overfrequency F Without additional functions In stock
7SD8011-5EB90-1FA0 L0R Circuit Breaker Line differential protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals region world, IEC/ANSI language English (language can be changed) front membrane standard system interface port B (device bottom side, on front) IEC 61850, 100 Mbit Ethernet, electr., double, RJ45 plug without further communication interface for Port A measurement: fault recording functionality line differential protection inrush-current detection overcurrent protection phase I>, I>>,I>>>, Ip overcurrent protection ground In>.In>>,In>>>, Inp thermal overload protection trip-circuit supervision circuit-breaker failure protection restart inhibit intertripping scheme external trip initiation parameter set switchover supervision functions circuit-breaker test circuit-breaker control flexible protection functions undervoltage/overvoltage V underfrequency/overfrequency F without supplementary functions. In stock
7SD8011-5EB90-1FA1 L0S Circuit Breaker Line differential protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) IEC 61850, 100 Mbit Ethernet, with integrated switch optical, double, LC duplex plug without further communication interface for Port A Measurement: fault recording Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>,I>>>, Ip Time-overcurrent protection ground In>.In>>,In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V Underfrequency/overfrequency F Additional function: Transmission of 16 binary signals (via interface) In stock
7SD8011-5EB90-3FA0 L0S Circuit Breaker Line differential protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug Measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A Rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, front) IEC 61850, 100 Mbit Ethernet, with integrated switch optical, double, LC duplex plug without further communication interface for Port A Measurement: Fault recording Mean value formation, min./max. values Functionality Line differential protection Inrush current detection Time-overcurrent protection phase I>, I>>,I>>>, Ip Time-overcurrent protection ground In>.In>>,In>>>, Inp Thermal overload protection Trip circuit monitoring Circuit breaker failure protection Closing lockout Circuit breaker intertrip External trip initiation Parameter set switchover Monitoring functions Circuit breaker test Control of circuit breaker Flexible protection functions Undervoltage/overvoltage V Underfrequency/overfrequency F Without additional functions In stock
7SD8021-5EB90-1FA0 L0S Circuit Breaker Line differential protection Enclosure 1/6 19", 4 x I, 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals region world, IEC/ANSI language English (language can be changed) front membrane standard system interface port B (device bottom side, on front) IEC 61850, 100 Mbit Ethernet, with integrated switch optical, double, LC duplex plug without further communication interface for Port A measurement: fault recording functionality line differential protection inrush-current detection overcurrent protection phase I>, I>>,I>>>, Ip overcurrent protection ground In>.In>>,In>>>, Inp thermal overload protection trip-circuit supervision circuit-breaker failure protection restart inhibit intertripping scheme external trip initiation parameter set switchover supervision functions circuit-breaker test circuit-breaker control flexible protection functions undervoltage/overvoltage V underfrequency/overfrequency F without supplementary functions. In stock
7SD8021-5EB90-1FA1 L0A Circuit Breaker Line differential protection Enclosure 1/6 19", 4 x I, 7 BI, 8 BQ (2 changeover contacts) 1 live contact Interface FOC for mono (24 km)/multimode fiber (4 km), LC duplex plug measuring inputs: Iph = 1 A / 5 A, Ie = 1 A / 5 A rated auxiliary power: 60 V/ 110 V / 125 V/ 220 V/ 250 V DC 115 V / 230 V AC Installation enclosure, screw terminals region world, IEC/ANSI language English (language can be changed) front membrane standard system interface port B (device bottom side, on front) PROFIBUS DP slave, electr. RS485 without further communication interface for Port A measurement: fault recording functionality line differential protection inrush-current detection overcurrent protection phase I>, I>>,I>>>, Ip overcurrent protection ground In>.In>>,In>>>, Inp thermal overload protection trip-circuit supervision circuit-breaker failure protection restart inhibit intertripping scheme external trip initiation parameter set switchover supervision functions circuit-breaker test circuit-breaker control flexible protection functions undervoltage/overvoltage V underfrequency/overfrequency F supplementary function: transmission of 16 binary signals (via protection interface) In stock

Product Information

Product Details

Relay 7SJ6001-2DA00-1DA0
7SJ6001-2DA00-1DA0

Relay 7SJ6001-2DA00-1DA0

View Details
Protective Relay 7SJ6225-5EB62-1FE0
7SJ6225-5EB62-1FE0

Protective Relay 7SJ6225-5EB62-1FE0

View Details
Overcurrent Protection Relay 7SJ8041-5EG90-1FC0 L0D
7SJ8041-5EG90-1FC0 L0D

Overcurrent Protection Relay 7SJ8041-5EG90-1FC0 L0D

View Details
Overcurrent Protection Relay 7SJ8021-5EB90-1FA1 L0S
7SJ8021-5EB90-1FA1 L0S

Overcurrent Protection Relay 7SJ8021-5EB90-1FA1 L0S

View Details
Relay 7VK6101-5AB31-4YR0
7VK6101-5AB31-4YR0

Relay 7VK6101-5AB31-4YR0

View Details
P1 Panelboard P1A6893-42 (7-SA86)
P1A6893-42 (7-SA86)

P1 Panelboard P1A6893-42 (7-SA86)

View Details
Differential Protection Relay 7UT6121-4EB91-1AA0
7UT6121-4EB91-1AA0

Differential Protection Relay 7UT6121-4EB91-1AA0

View Details
Protective Relay 7SJ6425-5EB92-3FA4 L0D
7SJ6425-5EB92-3FA4 L0D

Protective Relay 7SJ6425-5EB92-3FA4 L0D

View Details
Relay 7SR2303-1NA32-0CA0
7SR2303-1NA32-0CA0

Relay 7SR2303-1NA32-0CA0